Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
3.
Medicina (Kaunas) ; 59(8)2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37629700

RESUMO

Background: Noninvasive ventilation (NIV) provides positive pressure through different interfaces. A multifunctional full-face mask prototype was developed to provide NIV from three sources: ICU ventilators, portable ventilators, and high-flow medical gas pipeline systems. This study aimed to evaluate the usability of this prototype mask. Methods: This was a quantitative experimental study, conducted in two phases: the development of a full-face mask prototype NIV interface, and the evaluation of its usability by health professionals (evaluators) using a heuristic approach. The Wolf Mask prototype is a multifunctional full-face mask that makes it possible to deliver positive pressure from three different sources: microprocessor-controlled ICU ventilators, portable ventilators with single-limb circuits, and high-flow medical gas. The evaluation was conducted in three stages: presentation of the prototype to the evaluators; skills testing via simulation in a clinical environment; and a review of skills. Results: The prototype was developed by a multidisciplinary team and patented in Brazil. The evaluators were 10 health professionals specializing in NIV. Seven skills related to handling the prototype were evaluated. Three of the ten evaluators called for (non-urgent) changes to improve recognition of the components of the prototype. Only one evaluator called for (non-urgent) changes to improve recognition of the pieces, assembly, and checking the mask. Conclusions: The newly developed multifunctional full-face mask prototype demonstrated excellent usability for providing noninvasive ventilation from multiple sources. Minor modifications may further improve the design.


Assuntos
Ventilação não Invasiva , Máscaras , Respiração Artificial , Brasil , Simulação por Computador
5.
Artigo em Inglês | MEDLINE | ID: mdl-35575424

RESUMO

OBJECTIVES: Approaches to improve saphenous vein (SV) patency in coronary artery bypass graft (CABG) surgery remain relevant. This study aimed to evaluate the effects of different preservation solutions and different pressures of intraluminal distention on the endothelium of SV segments in CABG. METHODS: Forty-two SV segments obtained from 12 patients undergoing CABG were divided into 7 groups. Group 1 (control) was prepared without preservation or intraluminal distension, while the other 6 groups were preserved in autologous heparinized autologous arterial blood or normal saline (NS), with distention pressures 30, 100 and 300 mmHg. To assess the effects of using these solutions and pressures on the endothelium, the grafts were analysed by scanning electron microscopy, with the measurement of endothelial damage degree. RESULTS: Segments in group 1 showed minimal endothelial damage. SV grafts preserved with NS had significantly greater endothelial damage both compared to the control group and compared to groups preserved with autologous arterial blood (P < 0.001). Segments distended with pressures up to 100 mmHg showed less damage when compared to those distended at 300 mmHg, with the ones subjected to higher pressures presenting a maximum degree of damage, with considerable loss and separation of endothelial cells, extensive foci of exposure of the basement membrane and numerous fractures of the intimate layer, without differences regarding the solution used. CONCLUSIONS: Preparation of SV using NS and with intraluminal distension pressures above 100 mmHg is factors related to increased damage to the venous endothelium.


Assuntos
Células Endoteliais , Veia Safena , Ponte de Artéria Coronária , Dilatação Patológica , Endotélio Vascular , Humanos
6.
Oral Dis ; 28(6): 1705-1714, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33825326

RESUMO

OBJECTIVES: To verify the presence of Streptococcus mutans (S. mutans) in atherosclerotic plaque (AP) using techniques with different sensitivities, correlating with histological changes in plaque and immunoexpression of inflammatory markers. MATERIALS AND METHODS: Thirteen AP samples were subjected to real-time polymerase chain reaction (qRT-PCR), histopathological analyses, histochemical analysis by Giemsa staining (GS), and immunohistochemical analysis for S. mutans, IL-1ß, and TNF-α (streptavidin-biotin-peroxidase method). Ten necropsy samples of healthy vessels were used as controls. RESULTS: All AP samples showed histopathological characteristics of severe atherosclerosis and were positive for S. mutans (100.0%) in qRT-PCR and immunohistochemical analyses. GS showed that Streptococcus sp. colonized the lipid-rich core regions and fibrous tissue, while the control group was negative for Streptococcus sp. IL-1ß and TNF-α were expressed in 100% and 92.3% of the AP tested, respectively. The control samples were positive for S. mutans in qRT-PCR analysis, but negative for S. mutans, IL-1ß, and TNF-α in immunohistochemical analyses. CONCLUSION: The detection of S. mutans in AP and the visualization of Streptococcus sp. suggested a possible association between S. mutans and atherosclerosis. The results obtained from the control samples suggested the presence of DNA fragments or innocuous bacteria that were not associated with tissue alteration. However, future studies are necessary to provide more information.


Assuntos
Aterosclerose , Cárie Dentária , Placa Aterosclerótica , Cárie Dentária/microbiologia , Humanos , Streptococcus mutans/genética , Streptococcus sobrinus , Fator de Necrose Tumoral alfa
13.
Rev. bras. cir. plást ; 33(1): 39-47, jan.-mar. 2018. ilus, tab
Artigo em Inglês, Português | LILACS | ID: biblio-883636

RESUMO

Introdução: O dorso reto tem sido sempre um ideal na rinoplastia estética. A simples remoção da giba tem sido o método clássico e mais utilizado, mas pode ter consequências estéticas e funcionais adversas. Ainda existe grande resistência a procedimentos de aumento, porque a maioria dos pacientes solicitam redução e porque os benefícios de melhoria do equilíbrio nasal pelo aumento não são intuitivos. Um nariz aumentado pode parecer menor, o que é um benefício em particular em pacientes com pele espessa ou com o aspecto de terço inferior grande. Por outro lado, a percepção de redução com o aumento do radix e da ponta é muito comum, embora nunca tenha sido medida. Métodos: Esse estudo cria intervenções gráficas e reais para criar um dorso reto por meio do aumento do radix e da ponta e analisa como os pacientes e observadores independentes percebem as modificações. Analisou-se uma amostra de 42 casos consecutivos de rinoplastia. Desses, foram incluídos os que tinham dorso convexo e eram cirurgias primárias, restando 9 casos. Resultados: Houve aumento médio de 6,5% no tamanho do nariz na após a modificação gráfica, enquanto houve percepção de redução do nariz (p = 0,004). Houve aumento médio de 1% após a rinoplastia, enquanto houve percepção de redução. Conclusão: A retificação do dorso nasal pelo aumento do radix e da ponta causa percepção de redução do nariz.


Introduction: A straight bridge has always been the aesthetic ideal. Simple hump removal, the classical and most commonly applied method, can have aesthetic and functional consequences. However, great resistance to augmentation procedures persists because most patients request reduction and the benefits of improving nasal balance are counterintuitive. An augmented nose can look smaller, a particular benefit in patients with thick, inelastic skin or a large lower nose. On the other hand, decreased size perception after raising of the radix and tip is very common but has not been measured to date. Methods: This study created graphic and real interventions to achieve a straight bridge through radix and tip raising and analyzed how patients and independent observers perceive these changes. A sample of 42 sequential rhinoplasty patients was analyzed, including nine cases of primary surgery and dorsal convexity. Results: There was a 6.5% mean augmentation after graphic computing intervention but a perception of size reduction (p = 0.004). There was a 1% mean augmentation after rhinoplasty and an overall size reduction perception. Conclusion: Correction of the nasal dorsum, making a straight bridge through slightly increasing radix and tip, creates the perception of a decreased nose size.


Assuntos
Humanos , Feminino , Adulto , História do Século XXI , Rinoplastia , Procedimentos Cirúrgicos Operatórios , Percepção de Tamanho , Nariz , Procedimentos de Cirurgia Plástica , Cartilagens Nasais , Rinoplastia/efeitos adversos , Rinoplastia/métodos , Procedimentos Cirúrgicos Operatórios/efeitos adversos , Procedimentos Cirúrgicos Operatórios/métodos , Percepção de Tamanho/classificação , Nariz/anormalidades , Nariz/cirurgia , Procedimentos de Cirurgia Plástica/efeitos adversos , Procedimentos de Cirurgia Plástica/métodos , Cartilagens Nasais/anatomia & histologia , Cartilagens Nasais/anormalidades , Cartilagens Nasais/cirurgia
14.
Rev. bras. cir. cardiovasc ; 31(5): 351-357, Sept.-Oct. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-829758

RESUMO

Abstract Objective: Composite graft of left internal thoracic artery and great saphenous vein in revascularization of the left coronary system is a technique well described in literature. The aim of this study is to analyze blood flow dynamics in this configuration of composite graft especially in what concerns left internal thoracic artery's adaptability and influence of great saphenous vein segment on left internal thoracic artery's flow. Methods: Revascularization of left coronary system with composite graft, with left internal thoracic artery revascularizing the anterior interventricular artery and a great saphenous vein segment, anastomosed to the left internal thoracic artery, revascularizing another branch of the left coronary system, was performed in 23 patients. Blood flow was evaluated by transit time flowmetry in all segments of the composite graft (left internal thoracic artery proximal segment, left internal thoracic artery distal segment and great saphenous vein segment). Measures were performed in baseline condition and after dobutamine-induced stress, without and with non-traumatic temporary clamping of the distal segments of the composite graft. Results: Pharmacological stress resulted in increase of blood flow values in the analyzed segments (P<0.05). Non-traumatic temporary clamping of great saphenous vein segment did not result in statistically significant changes in the flow of left internal thoracic artery distal segment, both in baseline condition and under pharmacological stress. Similarly, non-traumatic temporary clamping of left internal thoracic artery distal segment did not result in statistically significant changes in great saphenous vein segment flow. Conclusion: Composite grafts with left internal thoracic artery and great saphenous vein for revascularization of left coronary system, resulted in blood flow dynamics with physiological adaptability, both at rest and after pharmacological stress, according to demand. Presence of great saphenous vein segment did not alter physiological blood flow dynamics in distal segment of left internal thoracic artery.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Veia Safena/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Ponte de Artéria Coronária/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Anastomose de Artéria Torácica Interna-Coronária , Artéria Torácica Interna/fisiologia , Resistência Vascular/fisiologia , Grau de Desobstrução Vascular/fisiologia , Estudos Prospectivos , Enxerto Vascular , Período Intraoperatório
16.
Int J Cardiol ; 174(3): 710-2, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24820755

RESUMO

BACKGROUND: Oral bacteria have been detected in atherosclerotic plaques at a variable frequency; however, the connection between oral health and vascular and oral bacterial profiles of patients with vascular disease is not clearly established. The aim of this study was to evaluate the presence of oral bacterial DNA in the mouth and atherosclerotic plaques, in addition to assessing the patients' caries and periodontal disease history. METHODS: Thirty samples of supragingival and subgingival plaque, saliva and atherosclerotic plaques of 13 patients with carotid stenosis or aortic aneurysm were evaluated, through real-time polymerase chain reaction, for the presence of Streptococcus mutans (SM), Prevotella intermedia (PI), Porphyromonas gingivalis (PG) and Treponema denticola (TD). All patients were submitted to oral examination using the DMFT (decayed, missing and filled teeth) and PSR (Periodontal Screening and Recording) indexes. Histopathological analysis of the atherosclerotic plaques was performed. RESULTS: Most of the patients were edentulous (76.9%). SM, PI, PG and TD were detected in 100.0%, 92.0%, 15.3% and 30.7% of the oral samples, respectively. SM was the most prevalent targeted bacteria in atherosclerotic plaques, detected in 100% of the samples, followed by PI (7.1%). The vascular samples were negative for PG and TD. There was a statistically significant difference (p<0.05) between the presence of PG and TD in the oral cavity and vascular samples. CONCLUSION: SM was found at a high frequency in oral and vascular samples, even in edentulous patients, and its presence in atherosclerotic plaques suggests the possible involvement of this bacterium in the disease progression.


Assuntos
Biofilmes , DNA Bacteriano/isolamento & purificação , Boca/microbiologia , Doenças Periodontais/diagnóstico , Doenças Periodontais/microbiologia , Placa Aterosclerótica/diagnóstico , Placa Aterosclerótica/microbiologia , Idoso , Idoso de 80 Anos ou mais , DNA Bacteriano/genética , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Boca Edêntula/diagnóstico , Boca Edêntula/genética , Boca Edêntula/microbiologia , Doenças Periodontais/genética , Placa Aterosclerótica/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos
17.
Rev Bras Cir Cardiovasc ; 28(2): 167-75, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23939312

RESUMO

OBJECTIVES: The purpose of our study was to establish, with an entirely noninvasive method, transthoracic Doppler echocardiography, criteria for patency of composite left internal thoracic artery grafts when placed on the left anterior descending artery and other branches of the left coronary system. METHODS: The control group comprised 20 patients with single graft and 20 patients with composite graft; all forty having their patency confirmed by coronary angiogram (CA). In this control group, two Doppler echocardiographic variables, diastolic mean velocity-time and integral diastolic peak velocity to systolic peak velocity ratio were recorded. For each variable, established cut-off points were established, using the ROC (Receiver Operator Characteristic) curves, to identify criteria which could differentiate the composite grafts. Only patients with composite grafts were included in the 159-patients study group. The criteria established by the cut-off points in the control group were then applied to detect patency using a diastolic fraction of > 0.5 as the gold standard. The sensitivity, specificity, and positive and negative predictive values of these two criteria were determined. RESULTS: In the control group, cut-off points of 0.71 and 0.09 m were established for the diastolic peak velocity/systolic peak velocity ratio and for diastolic mean velocity-time integral, respectively. In the study group phase, the sensitivity and negative predictive value of the diastolic peak velocity/systolic peak velocity > 0.71 criterion were 36% and 11%, respectively. Diastolic mean velocity-time integral > 0.09 m criterion, were 40% and 10.48%. The specificities and positive predictive values of each criterion were 100%. CONCLUSION: Values reaching the criteria established for each variable indicate high probability of composite graft patency. Lower values have a large proportion of false negatives and are not conclusive as patency criteria.


Assuntos
Ecocardiografia Doppler/normas , Artéria Torácica Interna/diagnóstico por imagem , Enxerto Vascular , Grau de Desobstrução Vascular , Adulto , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Ponte de Artéria Coronária/métodos , Diástole/fisiologia , Feminino , Humanos , Masculino , Artéria Torácica Interna/transplante , Pessoa de Meia-Idade , Curva ROC , Valores de Referência , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Sístole/fisiologia
18.
Rev. bras. cir. cardiovasc ; 28(2): 167-175, abr.-jun. 2013. ilus, tab
Artigo em Inglês | LILACS | ID: lil-682426

RESUMO

OBJECTIVES: The purpose of our study was to establish, with an entirely noninvasive method, transthoracic Doppler echocardiography, criteria for patency of composite left internal thoracic artery grafts when placed on the left anterior descending artery and other branches of the left coronary system. METHODS: The control group comprised 20 patients with single graft and 20 patients with composite graft; all forty having their patency confirmed by coronary angiogram (CA). In this control group, two Doppler echocardiographic variables, diastolic mean velocity-time and integral diastolic peak velocity to systolic peak velocity ratio were recorded. For each variable, established cut-off points were established, using the ROC (Receiver Operator Characteristic) curves, to identify criteria which could differentiate the composite grafts. Only patients with composite grafts were included in the 159-patients study group. The criteria established by the cut-off points in the control group were then applied to detect patency using a diastolic fraction of > 0.5 as the gold standard. The sensitivity, specificity, and positive and negative predictive values of these two criteria were determined. RESULTS: In the control group, cut-off points of 0.71 and 0.09m were established for the diastolic peak velocity/systolic peak velocity ratio and for diastolic mean velocity-time integral, respectively. In the study group phase, the sensitivity and negative predictive value of the diastolic peak velocity/systolic peak velocity > 0.71 criterion were 36% and 11%, respectively. Diastolic mean velocity-time integral > 0.09m criterion, were 40% and 10.48%. The specificities and positive predictive values of each criterion were 100%. CONCLUSION: Values reaching the criteria established for each variable indicate high probability of composite graft patency. Lower values have a large proportion of false negatives and are not conclusive as patency criteria.


OBJETIVO: O objetivo deste estudo é estabelecer parâmetros preditores de perviedade, avaliados por Dopplerfluxometria, do enxerto composto de artéria torácica interna esquerda, quando revasculariza a artéria interventricular anterior e outro ramo do sistema esquerdo. MÉTODOS: O grupo controle foi formado por 20 pacientes com enxerto simples e 20 pacientes com enxerto, composto cuja perviedade foi confirmada por cineangiocoronariografia. No grupo controle, as variáveis de fluxo relação velocidade pico diastólico/velocidade pico sistólico e integral da velocidade média/tempo na diástole foram registradas. Para cada variável, estabeleceram-se pontos de corte para identificar enxertos compostos, usando-se curvas ROC (receiver operator characteristic). No grupo estudo, foram avaliados 159 pacientes com enxerto composto, determinando-se os dois parâmetros de fluxo. Pontos de cortes estabelecidos no grupo controle foram usados para determinar sensibilidade, especificidade, valores preditivos positivo e negativo de cada variável relacionada à perviedade dos enxertos, tomando-se como referência a fração diastólica > 0,5. RESULTADOS: No grupo controle, os pontos de corte estabelecidos para as variáveis velocidade pico diastólico/velocidade pico sistólico e integral velocidade média/tempo na diástole foram, respectivamente, 0,71 e 0,09m. No grupo estudo, a sensibilidade para a velocidade pico diastólico/velocidade pico sistólico e integral da velocidade média/tempo na diástole, considerando seus pontos de corte, foi de 36,4% e 40%, respectivamente. Os respectivos valores preditivos negativos foram 11% e 10.48%, enquanto especificidade e valor preditivo positivo foram de 100% para os dois parâmetros. CONCLUSÃO: Valores maiores ou iguais aos estabelecidos para cada variável indicam alta probabilidade de perviedade do enxerto composto. Valores inferiores apresentam grande proporção de falsos negativos, não sendo conclusivos quanto à perviedade.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ecocardiografia Doppler/normas , Artéria Torácica Interna , Enxerto Vascular , Grau de Desobstrução Vascular , Velocidade do Fluxo Sanguíneo , Ponte de Artéria Coronária/métodos , Diástole/fisiologia , Artéria Torácica Interna/transplante , Valores de Referência , Reprodutibilidade dos Testes , Curva ROC , Estatísticas não Paramétricas , Sístole/fisiologia
19.
Rev Bras Cir Cardiovasc ; 26(3): 469-76, 2011.
Artigo em Inglês, Português | MEDLINE | ID: mdl-22086586

RESUMO

OBJECTIVE: To evaluate and validate, in our laboratory, the essay of myocardial infarction induced by isoproterenol in rats by means of analysis of hematological, biochemical, oxidative stress markers and histopathological parameters. METHODS: Thirty young, male, Wistar rats (145 to 230 g) were randomly allocated in two groups: Sham group, which underwent a virtual myocardial infarction induction, and the Infarction group, which underwent a myocardial infarction induction with isoproterenol. The administrations for the infarction induction were performed during two consecutive days and a 24-hour interval between them. Twenty-four hours after the last administration, rats from both groups were anesthetized and sacrificed for blood sample collection to evaluate complete blood count (CBC) and biochemical parameters (SGOT, SGPT, troponin I, urea and creatinin), obtain myocardial fragments for oxidative stress markers analyses (catalase activity and glutathione concentrations) as well as histopathological examinations. RESULTS: There were no death cases in the Sham group, while the mortality rate in the Infarction group was 25%. Myocardial infarction induction with isoproterenol raised leukocytes and neutrophils counts, SGOT, troponin I and urea concentrations, reduced catalase enzyme activity and glutathione concentrations in the myocardium and let to histopathological concentrations as well. It did not exert alterations in terms of hemoglobin, SGPT and creatinin concentrations. CONCLUSIONS: The isoproterenol-induced myocardial infarction essay in rats was adequately reproduced in our laboratory, causing alterations in hematological, biochemical, oxidative stress markers and histopathological parameters.


Assuntos
Aspartato Aminotransferases/sangue , Cardiotônicos/efeitos adversos , Catalase/sangue , Glutationa/sangue , Isoproterenol/efeitos adversos , Infarto do Miocárdio/induzido quimicamente , Troponina I/sangue , Animais , Biomarcadores/sangue , Modelos Animais de Doenças , Masculino , Infarto do Miocárdio/sangue , Infarto do Miocárdio/patologia , Estresse Oxidativo/fisiologia , Distribuição Aleatória , Ratos , Ratos Wistar
20.
Rev Bras Cir Cardiovasc ; 26(1): 131-4, 2011.
Artigo em Inglês, Português | MEDLINE | ID: mdl-21881723

RESUMO

We present a case of brachial artery infected aneurysm in a patient with infective endocarditis caused by Streptococcus bovis. A 49-year-old man presented with fever dyspnea and a pansystolic murmur with irradiation to axilla. The echocardiogram revealed vegetation in native mitral valve. After mitral valve replacement with bioprosthesis, it was observed pulsatile mass of five centimeters in diameter at antecubital fossa of right upper limb. It was made the diagnosis of infected aneurysm of the brachial artery, and the surgery was performed successfully. The aim of this case report is to show a rare complication after infective endocarditis.


Assuntos
Aneurisma Infectado/cirurgia , Artéria Braquial , Endocardite Bacteriana/complicações , Valva Mitral/cirurgia , Streptococcus bovis , Aneurisma Infectado/microbiologia , Endocardite Bacteriana/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...